GeoVision GV-AS2120 IP Control Panel User Manual
Page 176

174
In the Output Condition settings, these
Output Type
and
Output Condition
become
available:
Output Type Output Condition
Door #
Gate #
Relay #
Input/Reader
Normal
Toggle
Pulse
Access Granted Access Granted Access Granted Select
None
to
disable the
condition, or select
an Input, Wiegand,
or Reader to
trigger the output.
Access Denied
Access Denied
Access Denied
Fire Alarm
Fire Alarm
Fire Alarm
Tamper
Tamper
Tamper
Duress Event
Duress Event
Duress Event
Held Open
Held Open
Forced Open
Forced Open
Exit Button
Exit Button
Door Contact
Car Detection
Click
Reset
button to return the
Normal
,
Toggle
or
Pulse
triggered state to be normal.
Click
Submit
button to save the changes, or click
Cancel
button to return the changes to its
previous state.
Note:
The
Reset
button is more commonly used for the
Toggle
output because once
triggered, the output will go on forever. A
Reset
button is needed to turn it off.