2 connecting input devices – GeoVision GV-AS2120 IP Control Panel User Manual
Page 59

GV-AS110 / 1110 Controller
57
2
2.2.2 Connecting Input Devices
GV-AS110 supports 3 types of inputs, while GV-AS1110 supports 2 types of inputs.
1.
GV-AS110 / 1110:
Sensor inputs, e.g. door status sensor
2.
GV-AS110 / 1110:
Button inputs, e.g. door opener
3.
GV-AS110 only:
Fire Sensor inputs, e.g. fire detector
All inputs are
dry contact
and can be configured as normally open (NO) or normally closed
(NC) through the keypad. The default value is
NO
. To change the input status, see the
Select Input Contact Type
option in
2.3.2 Programming the GV-AS110 / 1110
.
The tables below show the wire assignments of input connectors on GV-AS110 and GV-
AS1110.
GV-AS110
Wire color
Definition
Yellow
Door Sensor IN1
Orange
Button IN2
LRed
Fire Sensor IN3
Brown
IN COM (GND)
GV-AS1110
Wire color
Definition
Green
IN COM (GND)
Blue
Door Sensor IN1
Purple
Button IN2