6 fitting the battery, Battery – GeoVision GV-AS2120 IP Control Panel User Manual
Page 37

GV-AS100 / 1010 Controller
35
1
1.2.6 Fitting the Battery
GV-AS100 / 1010 includes a battery, providing power to GV-AS100 / 1010 settings and real-
time clock circuitry. When the power in the battery becomes low, the message
“Low Battery”
will appear on GV-AS100 / 1010 LCD. In this case, replace the battery. All settings on GV-
AS100 / 1010 will disappear about 10 hours after the battery stops working, and GV-AS100 /
1010 will be restored to default settings.
Battery
Door
19 NO
Door
18 NC
Door
17 COM
Alarm
16 NO
Alarm
15 COM
14 IN
COM
13 IN3
Fire
12 IN2
Button
11 IN1
Sensor
Battery
GV-AS100
GV-AS1010
Figure 1-14
Note:
1. Make sure the plastic insulation film under the battery is removed.
2. It is recommended to replace the battery annually. GV-AS100 uses a 3V lithium
battery that can be purchased on your own. For GV-AS1010, contact your sales
representative to acquire replacement batteries designated for GV-AS1010.