The Web Interface
179
8
=
4
7
3. To allow network connection, you must also enable network connection to the
controller on the Web interface of the GV-CR420 or GV-GF1921 / 1922.
4.
Refer to the table for connecting GV-CR420 and GV-AS Controllers through network.
CR420 V1.0
CR420 V1.01
GV-AS210 / 410 / 810 V1.1 or later
GV-EV48
GV-AS1010 / 1110 / 2110 / 2120 / 4110 / 8110
Not
Supported
MAC Address
GV-AS210 / 810 V1.0
GV-AS100 / 110 / 120 with ASBox / ASNet
Barcode
Not Supported
[Read Mode]
Only for GV-R1352 / RK1352 / DFR1352 (Rev. B). Set the connected reader
to read
UID
(unique identifier) or
GID
(GeoVision ID) on the card / key fob. If you select
Read GID
, make sure your card / fob has two sets of digits, as illustrated below. If your card
/ fob has only one set of digits, GID is not supported and you must select
Unique
Identification (UID)
.
138,08572
14001110
UID
GID
140
01164
138,08
572
UID
GID
Figure 8-26
Note:
GID is only supported by GV-R1352 / RK1352 / DFR1352 (Rev. B) with firmware
V1.2 or later.