3 connecting output devices – GeoVision GV-AS2120 IP Control Panel User Manual
Page 60

58
2.2.3 Connecting Output Devices
GV-AS110 supports 2 types of outputs, while GV-AS1110 supports 1 type of output:
1.
GV-AS110 only:
Alarm outputs, e.g. siren or bell
2.
GV-AS110 / 1110:
Door outputs, e.g. electronic lock
The table below shows the wire assignments of output connectors on GV-AS110 and GV-
AS1110.
GV-AS110
Wire color
Definition
Purple
Alarm COM
Gray
Alarm NO
Brown & White Door COM
Black & White
Door NC
Light green
Door NO
GV-AS1110
Wire color
Definition
Brown
Door A Com
Yellow
Door A NC
Orange
Door A NO
Check if your output device meets the following absolute maximum ratings before
connecting it to the Door outputs.
Breakdown Voltage
250V AC, 220V DC
Continuous Load Current
1A (30V DC), 0.3A (125V AC)
Note:
Absolute Maximum Ratings are those values beyond which damage to GV-
AS110 / 1110 circuit board may occur. Continuous operation of GV-AS110 at the