The configuration and functions of the
Auto Nozzle Check Settings
tab in the Printer settings screen are shown
below.
After changing the settings in items
B
to
G
, the changes are applied by clicking
Set
.
Item
Functions
A
Apply to all printers
By selecting this, the results of settings changed in
B
to
G
are batch applied to
all printers displayed in the printer list area at the top of the screen.
Select this and then change the settings in
B
to
G
, and then click
Set
.
B
Auto Nozzle Check Settings
Set the conditions in which an automatic nozzle check is done. Select one of the
following.
❏
High quality
You can print at high print quality because you can execute a Nozzle Check
automatically before printing and stop printing if clogged nozzles are
detected while printing.
You can set all the items from
C
to
G
.
❏
Normal
Automatic nozzle check is done less frequently than when
High quality
is
set.
Nozzle Check before printing
(
C
) and
Action when printing trouble is
detected
(
G
) are disabled. Also, you can set more sheets for executing
Periodic Check
(
D
) than the number of sheets when
High quality
is set.
❏
Off
Nozzles are not checked automatically. Select his when you want to visually
confirm the printed check pattern to confirm the state of the nozzles.
❏
Default
Returns all the settings (
B
to
G
) in the
Auto Nozzle Check Settings
tab to
the manufacturer’s settings.
C
Nozzle Check before printing
You can set this when
High quality
is selected in
Auto Nozzle Check Settings
(
B
).
Set whether to execute auto nozzle check before printing.
When set to
Auto
, auto Nozzle Check is executed according to the state of the
printer, such as after changing the auto nozzle check settings, or after executing
nozzle cleaning.
When set to
Every time
, auto nozzle check is executed for each print job.