beautypg.com

The t1 configuration window, The t1 configuration window -3 – Enterasys Networks 6000 User Manual

Page 220

background image

The T1 Configuration Window

8-3

HSIM-W87 Configuration

Line Status

This field indicates the line status of the interface. It contains loopback state and failure
state information. Scroll to view all of the status information, if necessary.

T3 Line Type

Select the type of DS3 or C-bit application implementing this interface: M23 or
CbitParity. The type of interface affects the interpretation of the usage and error
statistics.

T3 Loop Back

Select the loopback configuration of the T3 interface. Options are:

No Loop

Not in a loopback state. A device that is not capable of performing a
loopback on the interface will always have this value.

Payload

The received signal at this interface is looped through the device.
Typically the received signal is looped back for retransmission after it
has passed through the devices’s framing function.

Line Loop

The received signal at this interface does not go through the device, but
is looped back out.

Transmit Clock Source

Select the T3 Transmit Clock Source: Loop-Timing, which indicates that the recovered
receive clock is used as the transmit clock, or Local-Timing, which indicates that an
internal clock source is used.

To change an option in the T3 Config window:

1.

In the Line Type, Loop Back, and Transmit Clock Source sections, click to
select the desired option.

2.

Click the Apply button to set your changes.

The T1 Configuration Window

You can set certain variables for the DS1 connections using the T1 Config window. To
access the T1 Config window:

1.

Click on the appropriate Module Index to access the Module menu.

2.

Select HSIM W87 Config (T1). The T1 Config window,

Figure 8-2

, will

appear.