beautypg.com

Enterasys Networks 6000 User Manual

Page 155

background image

Alarm Configuration

4-20

Advanced Alarm Configuration

7.

Since the first sample taken can be misleading, you can use the selections in
the Startup Alarm box to disable either the rising or the falling threshold for
that sample only. If you would like to exclude the falling alarm, select the
Rising option; the first sample taken will only generate a rising alarm, even if
the sample value is at or below the falling threshold. To exclude the rising
alarm, select the Falling option; the first sample will then only generate a
falling alarm, even if the sample value is at or above the rising threshold. If
you wish to receive both alarms as appropriate, select the Both option.

8.

Use the selections in the Sample Type box to indicate whether you want your
threshold values compared to the total count for the variable during the
interval (Absolute), or to the difference between the count for the current
interval and the count for the previous interval (Delta). Make sure you have
set your thresholds accordingly.

9.

Click in the RisingThreshold field; enter the high threshold value for this
alarm.

10. There are two ways to assign an event to your rising threshold: click in the

RisingEventIndex text box and enter the number of the event you would like
to see triggered if the rising threshold is crossed; or use the Events Watch list
in the main Alarm/Event window to highlight the desired event, then click on
the Rising Event Index button. Be sure you assign the number of a valid
event or there will be no response if the selected variable meets or crosses
this threshold; assigning an index of zero effectively disables the threshold, as
there will be no indication that it has been crossed.

For more information on how events are triggered, see

How Rising and

Falling Thresholds Work

, on

page 4-27

.

11. Click in the FallingThreshold field; enter the low threshold value for this

alarm.

12. There are two ways to assign an event to your falling threshold: click in the

FallingEventIndex text box and enter the number of the event you would like
to see triggered if the falling threshold is crossed; or use the Events Watch list
in the main Alarm/Event window to highlight the desired event, then click on
the Falling Event Index button. Again, be sure you assign the number of a
valid event or there will be no response if the selected variable meets or
crosses this threshold; assigning an index of zero effectively disables the
threshold, as there will be no indication that it has been crossed.

For more information on how events are triggered, see

How Rising and

Falling Thresholds Work

, on

page 4-27

.

NOTE

There is no limit to the number of alarms that may be assigned to the same event.