Basic Alarm Configuration

4-5

Alarm Configuration

IF Type

Displays each interface’s type: e.g., FDDI, Ethernet, ATM. Note that there is no type
distinction between standard Ethernet and Fast Ethernet.

Status

Displays the current status of the selected alarm type for each interface: Enabled or
Disabled. Remember, this status refers only to the alarm type which is selected at the top
of the window; each of the other two alarm types can have different states.

Log/Trap

Indicates whether or not each alarm has been configured to create a silent log of event
occurrences and the alarms that triggered them, and whether or not each alarm has been
configured to issue a trap in response to a rising or falling alarm condition. Possible values
are log, trap, log&trap, or none.

Polling Interval

Displays the amount of time, in days, hours, minutes, and seconds, over which the selected
alarm variable will be sampled. At the end of the interval, the sample value will be
compared to both the

Rising Threshold

and

Falling Threshold

. You can set any interval

up to 24,855 days.

Rising Threshold

Displays the high threshold value set for the selected alarm variable. Values used to
compare to the thresholds are relative, or delta values (the difference between the value
counted at the end of the current interval and the value counted at the end of the previous
interval); be sure to set your thresholds accordingly.

Rising Action

These option buttons indicate whether or not a rising alarm occurrence will initiate any
actions in response to the alarm condition: Enable Port if bridging will be enabled at the
selected interface in response to a rising alarm, Disable Port if bridging will be disabled at
the selected interface in response to a rising alarm, or None if no actions have been
configured for the selected alarm. Note that the Action fields will be unavailable for
devices configured to operate in SecureFast switching mode, or that do not support the
Actions MIB.

Falling Threshold

Displays the low threshold value set for the selected alarm variable. Values used to
compare to the thresholds are relative, or delta values (the difference between the value
counted at the end of the current interval and the value counted at the end of the previous
interval); be sure to set your thresholds accordingly.

Falling Action

These option buttons indicate whether or not a falling alarm occurrence will initiate any
actions in response to the alarm condition: Enable Port if bridging will be enabled at the
selected interface in response to a falling alarm, Disable Port if bridging will be disabled
in response to a falling alarm, or None if no actions have been configured for the selected
alarm. Note that the Action fields will be unavailable for devices configured to operate in
SecureFast switching mode, or that do not support the Actions MIB.