5204SE-MNET-PDPMV1 ♦ ProLinx Gateway

Reference

Modbus TCP/IP to PROFIBUS DP-V1 Pass-Through Master

User Manual


Page 192 of 235

ProSoft Technology, Inc.

December 22, 2009

Variable Name

Size/Type

Description

In - Fault

1

16-bit
Integer

For details, see Write Class 1 Acyclic Data Message
Structure (page 216)

In -
AcyclicWriteActive

1

Single-bit
Boolean

The DFB will set this bit when the Modbus TCP/IP message
has been initiated and is being processed.

In - AcyclicWriteError 1

Single-bit
Boolean

The DFB will set this bit when the Modbus TCP/IP response
is not successfully received. When this bit is set, it indicates
your control and sequencing logic should retry the command.

In -
AcyclicWriteSuccess

1

Single-bit
Boolean

The DFB will set this bit when the Modbus TCP/IP response
is successfully received and the PROFIBUS cyclic input data
variables have been updated.