Variable Name

Size/Type Description

In - ConfigurationData

245-element
8-bit Byte
Array

Additional message data that may be returned by the
slave

In - MessageDone

1

Single-bit
Boolean

The DFB will set this bit when the Modbus TCP/IP
response is successfully received.

In - MessageError

1

Single-bit
Boolean

The DFB will set this bit when the Modbus TCP/IP
response is not successfully received. When this bit is
set, it indicates your control and sequencing logic should
retry the command.

DFB Acyclic Mailbox Message: Get Database Information - M340

This acyclic message fetches information about the stored database (user-
specific data that was downloaded to the gateway in message data bytes 1 to 32
via mailbox "FB_APPL_END_DATABASE_DOWNLOAD" or from the
configuration tool).

This message also returns information about the amount of allocated I/O data
space.

MNETDPV1_MAILVAR_GetDataBase Variables - M340

This variable structure is the one to use with your control and sequencing logic
when you want to send a request to retrieve information about the PROFIBUS
database.