Command and Response Layout: Get Live List

Command

Response

Message ID

(ID)

(ID)

Acyclic Message Status

Word

4002h

0002h

Command

0018h

0018h

Get Live List

Data size

0000h

007Fh

127 Bytes of Data

Frame count

0001h

0001h

Frame number

0001h

0001h

Offset high

0000h

0000h

Offset low

0000h

0000h

Extended word 1

-

-

Extended word 2

-

-

Extended word 3

-

-

Extended word 4

-

-

Extended word 5

-

-

Extended word 6

-

-

Extended word 7

-

Return Code

Extended word 8

-

Fault Information

Message Data byte 1

Station Type 0

Response Data Byte 1

Message Data byte 2

Station Type 1

Response Data Byte 1

Message Data byte 3

Station Type 2

Response Data Byte 1

...

...

Response Data Byte 1

Message Data byte "n"

Station Type 126

Response Data Byte 1

Acyclic Message Status Word
Refer to Acyclic Message Status Word (page 99).

Station Type [0 … 126]
00h: Slave Station
01h: Master Station not yet ready for Token ring (station only physically at the
bus)
02h: Master Station ready to enter Token ring (there is not yet any Token
transmission)
03h: Master Station in Token Ring (Token transmission through the station)
04h: Station does not exist

Fault Information
If "Invalid Other" is returned in the Acyclic Message Status Word in the header of
the response, information about the fault can be found here. Refer to Acyclic
Message Status Word (page 99).
0AH00: Failed to build Live List.
FF00h: Module offline (not initialized or no valid database)