Configuration
PROFIBUS DPV1 Master
Protocol Manual
ProSoft Technology, Inc.
Page 55 of 157
March 23, 2011
4 In the tree view, click the plus sign [+]
to expand the slave device you added.
This action opens a list of device configuration values. The following
illustration shows the possible input/output configuration values for a Siemens
EM 277. The selections available for other devices may be different, so you
should review the specifications for the product you are installing in order to
determine the correct values to use.
5 Drag the input and output parameters to the slot location grid (Subscriber
List) below the Bus Configuration window. The slot view displays the slot
number, configuration data, and input and output addresses. The PROFIBUS
DP Master uses this information to identify and communicate with individual
slaves on the network.