Command Guide of WGSW-48040HP

clock summer-time date

1-12>

Default:

N/A

Usage Guide:

To set daylight saving.

Example:

To set daylight saving (Started time: Feb, 3. 2013 8:8AM, End time: Dec, 31. 2013 8:8AM, Offset time: 60 minutes).

Switch# configure terminal

Switch (config)# clock summer-time 1 date 2 3 2013 8:8 12 31 2013 8:8 60

4.2.24 clock timezone

Command:

clock timezone

name of time zone

Default:

0

Usage Guide:

To set timezone.

Example:

To set timezone (GMT -15) with profile 1.

Switch# configure terminal

Switch (config)# clock timezone 1 -15

4.2.25 default access-list rate-limiter

Command:

default access-list rate-limiter

Rate limiter ID