beautypg.com

81 show pvlan, 82 show pvlan isolation – PLANET WGSW-48040HP User Manual

Page 354

background image

Command Guide of WGSW-48040HP

Default:

N/A

Usage Guide:

To display the external clock output configuration.

Example:

To display the external clock output configuration.

Switch # show ptp ext

PTP External One PPS mode: Output, Clock output enabled: True, frequency : 1, VCXO

enable: True

4.20.81 show pvlan

Command:

show pvlan [ ]

show Show running system information

pvlan PVLAN configuration

Default:

N/A

Usage Guide:

To display the Private VLAN membership configuration.

Example:

To display the Private VLAN membership configuration for all VLANs.

Switch # show pvlan

PVLAN ID Ports

-------- -----------------------------------------------------------------------------

1 GigabitEthernet 1/1, GigabitEthernet 1/2, GigabitEthernet 1/3,

4.20.82 show pvlan isolation

Command:

show pvlan isolation [ interface ( [ ] ) ]

show Show running system information

-354-