155 rmon event, 156 sfp temperature-threshold – PLANET WGSW-48040HP User Manual
Page 250

Command Guide of WGSW-48040HP
Switch# configure terminal
Switch (config)# rmon alarm 1 .1.3.6.1.2.1.2.2.1.10.15 50 absolute rising-threshold
1000 1 falling-threshold 520 1 falling
4.2.155 rmon event
Command:
rmon event
rmon Remote Monitoring
event Configure an RMON event
description Specify a description of the event
log Generate RMON log when the event fires
trap Generate SNMP trap when the event fires
Default:
None
Usage Guide:
To configure the Event of RMON
Example:
To configure the Event (below table) of RMON
Switch# configure terminal
Switch (config)# rmon event 1 log trap planet description error
4.2.156 sfp temperature-threshold
Command:
sfp temperature-threshold <0-100>
sfp temperature-threshold Set a lower high temperature threshold for the secondary
temperature alarm in degrees C.
<0-100> Specifies the new threshold temperature.
-250-