5 understanding the command structure, 6 addressing multiple power supplies, Understanding the command structure -61 – KEPCO MBT Series User Manual
Page 99: Addressing multiple power supplies -61

MBTSVC111609
3-61
Your GPIB interface card software will automatically send a message terminator. For example,
the HP BASIC OUTPUT statement inserts
exchanged,
data except binary data.
NOTE: Kepco power modules require a message terminator at the end of each program mes-
sage. The examples shown in this manual assume a message terminator will be added
at the end of each message. Where a message terminator is shown it is represented
as
3.3.5.5
UNDERSTANDING THE COMMAND STRUCTURE
Understanding the command structure requires an understanding of the subsystem command
tree illustrated in Figure 3-4. The “root” is located at the top left corner of the diagram. The
parser goes to the root if:
• a message terminator is recognized by the parser
• a root specifier is recognized by the parser
Optional keywords are enclosed in brackets [ ] for identification; optional keywords can be omit-
ted and the power supply will respond as if they were included in the message. The root level
keyword [SOURce] is an optional keyword. Starting at the root, there are various branches or
paths corresponding to the subsystems. The root keywords for the MBT-G power supply are
:INITiate, :MEASure, :OUTPut, [:SOURce], :STATus, and :SYSTem. Because the [SOURce]
keyword is optional, the parser moves the path to the next level, so that VOLTage, CURRent,
and FUNCtion commands are at the root level.
Each time the parser encounters a keyword separator, the parser moves to the next indented
level of the tree diagram. As an example, the STATus branch is a root level branch that has
three sub-branches: OPERation, PRESet, and QUEStionable. The following illustrates how
SCPI code is interpreted by the parser:
STAT:PRES
STAT:OPER?;PRES
by the colon in front of OPER?. Thus you can combine the following message units
STAT:OPER? and STAT:PRES;
STAT:OPER:COND?;ENAB 16
abbreviated notation for STAT:OPER:ENAB.
3.3.5.6
ADDRESSING MULTIPLE POWER SUPPLIES
Power supplies on the IEEE 1118 bus are selected by node address, also referred to as node
number or channel number. Refer to the applicable manuals for the power modules connected
to the IEEE 1118 bus to set each power module to a unique node number, from 1 to 31 (a maxi-
mum of 27 power modules may be connected to the bus).
The node number may follow any part of a SCPI command. Note that there must be no space
preceding the node number