5 cycling a program, 6 stopping a program, Cycling a program -39 – KEPCO MBT Series User Manual
Page 77: Stopping a program -39, D 3.2.1.11.5, D 3.2.1.11.5), Stp 0, End of program stp n, End of program, Stp n cycle on end of program

MBTSVC111609
3-39
Then press SHIFT then (DEL STEP function), until display reads:
NOTE: If step 0 is deleted, the initial values for step 0 of a new program will be the same as
the deleted step 0.
3.2.1.11.5 CYCLING A PROGRAM
1.
To cycle a program, first enter program mode and select a program. Press NEXT until the
display reaches the end of the program:
2.
Press SHIFT and 0. The display changes to:
3.
Press SHIFT then RESET to execute the program. The program will run continuously, pro-
ceeding to execute step 0 after the last step is executed.
3.2.1.11.6 STOPPING A PROGRAM
There are two ways to stop a program:
1.
Press CLEAR ENTRY key. The program will stop at the step in progress when CLEAR
ENTRY is pressed. The values programmed by that step will remain at the power supply
output. The display will be as shown below:
2.
Press RESET key. Operation of RESET is similar to CLEAR ENTRY above, with the fol-
lowing exception: pressing RESET forces the power supply output voltage and current to
zero. (For MR and MGR Models, the output is also disconnected from the load.)
To restart the program, press SHIFT then RESET to execute the program; the program will
restart from step 0 (Stp: 0).
Stp 0
End of program
Stp n
End of program
NOTE: n = the last step of the
program selected
Stp n Cycle On
End of program
VOLTAGE
MODE
CURRENT
MODE
POLARITY
REVERSED
REMOTE
OUTPUT
ENABLED
STATUS
xxx...
NOTE: xxx = the message will depend
on which screen is displayed.
The screen displayed prior to
running the program will be
displayed when the program
stops.
Pr# x Stp: x Sc:x
/1014