1 entering program mode, 2 creating a new program, Table 3-16. default parameters for new added steps – KEPCO MBT Series User Manual
Page 72: Entering program mode -34, Creating a new program -34, 16 default parameters for new added steps -34, Able 3-16, Ar. 3.2.1.11.1), Rev/change prg # ***v ***a, Stp 0

3-34
MBTSVC111609
3.2.1.11.1 ENTERING PROGRAM MODE
1.
Press SHIFT key. (Blinking sh appears on display.)
2.
Press MENU ON/OFF (REV/CHG PROGRAM) key
3.
Select a Program # (0 to 9) by pressing the corresponding number key. (It is not necessary
to press ENTER.)
a. If the program is new (empty - no programmed steps stored), the display changes to:
Proceed to PAR. 3.2.1.11.2 to create a program.
b. If the Program # selected (e.g., 2) has been previously stored, the display changes to
one of the screens shown in Table 3-15. (The screen displayed is related to the last
screen displayed during a prior programming session.)
Proceed to PAR. 3.2.1.11.3 to execute the program, or PAR. 3.2.1.11.4 to modify the
program.
3.2.1.11.2 CREATING A NEW PROGRAM
To create a new program (display appears as shown in PAR. 3.2.1.11.1, step 3, above) it is nec-
essary to insert “blank” steps using the ADD STEP function. These “blank” steps have the fol-
lowing default values listed in Table 3-4. Once the desired number of steps have been added,
programming the values is the same as described for reviewing/changing an existing program.
TABLE 3-16. DEFAULT PARAMETERS FOR NEW ADDED STEPS
PARAMETER
VALUE
VOLTAGE
0 V
CURRENT
0 A
DELAY
0.1 SEC
MODE
VOLTAGE
POLARITY
NON-REVERSED
OUTPUT
ENABLED
NOTE:
The default values shown above are only for a completely new step. If the step was previ-
ously programmed, deleted, and then added again, the previous values will appear.
Rev/change PRG #
***V ***A
NOTE: indicates that a blinking “:” will
appear if output is enabled.
Stp 0
End of program