9 reversing dc output polarity — mr, mgr models, Reversing dc output polarity — mr, mgr models -30, Const curr mode – KEPCO MBT Series User Manual
Page 68: V ***a, Polar reversed, V ###a

3-30
MBTSVC111609
2.
Press Iadj key to command the power supply to go into Current mode.; the display will
briefly display the message shown below:, then return to the “Output is OFF” or “Key-
pad Control” message displayed before the SHIFT key was pressed.
3.2.1.9
REVERSING DC OUTPUT POLARITY — MR, MGR MODELS
The display should be reading either “Output is off” (PAR. 3.2.1.5.1, step 1) if the output is
disabled, or “Keypad control” (PAR. 3.2.1.5.1, step 2) if the output is enabled.
1.
Press SHIFT key. (Blinking “sh” appears on display.)
2.
Press DC OFF (CHANGE POLARITY) key.
a.
If changing from non-reversed to reversed, the display briefly shows:
VOLTAGE
MODE
CURRENT
MODE
POLARITY
REVERSED
REMOTE
OUTPUT
ENABLED
STATUS
Const CURR mode
NOTE: If output is enabled, a blinking “:” appears at the center of the
bottom line of the display and the VOLTAGE MODE and CUR-
RENT MODE indicators reflect the actual mode of the power
supply as determined by the load.
***V ***A
VOLTAGE
MODE
CURRENT
MODE
POLARITY
REVERSED
REMOTE
OUTPUT
ENABLED
STATUS
Polar Reversed
NOTE: ###V and ###A represent
either actual power supply
output voltage and current
(output enabled) or pro-
grammed output and limit val-
ues (output disabled).
###V ###A
NOTES: indicates that blinking “:” appears only for OUTPUT ENABLED status.
The POLARITY REVERSED indicator will only go on when the output is
enabled.
A blinking “sh” is represented by
sh
to indicate that the SHIFT key has
been pressed, and the next key that is pressed will be interpreted with the
alternate meaning.