Table 3-10 (MR, MGR Models) summarizes the effect of the Iadj and numeric keys for different
conditions. The first three columns reflect the status of the unit before the Iadj command is
issued. The fourth column shows the message on the front panel display after the Iadj key is
pressed and the fifth column shows how the adjustment will affect the status of the power sup-
ply. Refer to PAR.s 3.1.1 and 3.1.2 for more details regarding commanded and actual mode of
operation (either voltage or current).

Table 3-10 shows that with the power supply output disabled, the Iadj and keypad entries adjust
the programmed output current (Current mode) or current limit (Voltage mode). The Iadj and
keypad entries operate similarly to control actual output current/current limit if the power supply
output is enabled, and the value of the load permits the power supply to operate in the com-
manded mode, Current/Voltage.

If the load is enabled, and the power supply is commanded to operate in Current mode, but
R

L

≥ V

Prog

/ I

Prog

forces the power supply to operate in voltage mode, the keypad entries adjust

the actual current limit, contrary to the display indication.

If the load is enabled, and the power supply is commanded to operate in Voltage mode, but
R

L

< V

Prog

/ I

Prog

forces the power supply to operate in Current mode, the keypad entries adjust

the actual output current, contrary to the display indication.

Refer to PAR. 3.2.1.7.3 for procedure.

TABLE 3-10. USING IADJ AND KEYPAD ENTRIES TO SET

OUTPUT CURRENT/CURRENT LIMIT — MODELS MR, MGR

POWER SUPPLY STATUS BEFORE Iadj PRESSED

EFFECT AFTER Iadj PRESSED

COMMANDED

MODE

OUTPUT

ENABLED/
DISABLED

ACTUAL MODE ***

(DICTATED BY

LOAD)

DISPLAY

INDICATION

NUMERIC VALUE

SET BY KEYPAD

ADJUSTS:

CURRENT

DISABLED

CURRENT*****

CONST CURR =

Programmed output current

VOLTAGE

DISABLED

VOLTAGE*****

CURR LIMIT =

Programmed current limit

CURRENT

ENABLED

CURRENT

CONST CURR =

Actual output current

CURRENT

ENABLED

VOLTAGE ****

CONST CURR =

Actual current limit **

VOLTAGE

ENABLED

VOLTAGE

CURR LIMIT =

Actual current limit

VOLTAGE

ENABLED

CURRENT ****

CURR LIMIT =

Actual output current **

*

If the unit was programmed to Current mode remotely before being set to Local Mode, the unit will stay in current
mode until a Voltage Mode command is received.

**

“Overload” error message placed in error buffer (for use when operating in Remote mode).

*** Actual mode is indicated by the VOLTAGE MODE and CURRENT MODE status LED’s.
**** Condition where load forces power supply mode
***** Forced by the power supply.