3-29

greater than or equal to the programmed voltage divided by programmed current, the power
supply will operate in Voltage mode (forced).

Commanding the power supply to go into Current mode (with output disabled) from Voltage
mode causes the output relays to put an internal short across the power supply output (allowing
the load to be connected/disconnected). With the output disabled the CURRENT indicator will
go on and the VOLTAGE indicator will go off. If the output is enabled, the actual mode will be
determined by the programmed voltage and current values relative to the load (see PAR.
3.2.1.7.1). To command the power supply to enter Current mode, proceed as follows:

1.

Press SHIFT key; display resembles A or B below.

VOLTAGE

MODE

CURRENT

MODE

POLARITY

REVERSED

REMOTE

OUTPUT

ENABLED

STATUS

Output is OFF

A

MR, MGR models with
Output disabled
(commanded) Voltage
Mode

NOTE: (If previously set to Current mode, VOLTAGE MODE indicator

is off and CURRENT MODE indicator is on (internally relays
short the output).

***V ***A sh

NOTE:

***V and ***A are
the output volt-
age and current
settings in effect
at time of last
operation (for
first time use, the
voltage and cur-
rent are set to 0).

VOLTAGE

MODE

CURRENT

MODE

POLARITY

REVERSED

REMOTE

OUTPUT

ENABLED

STATUS

Keypad control

B

MR, MGR models with
Output enabled
(actual) Voltage Mode

NOTE: Although Voltage mode is shown above, the actual mode is