beautypg.com

3 procedure using vadj and numeric keypad, Procedure using vadj and numeric keypad -13, R. 3.2.1.6.3 for p – KEPCO MBT Series User Manual

Page 51: Const volt = ###v ###a, Volt limit = ###v ###a

background image

MBTSVC111609

3-13

If the output is enabled, and the power supply is commanded to operate in Voltage mode, but
R

L

< V

Prog

/ I

Prog

forces the power supply to operate in current mode, the keypad entries adjust

the actual voltage limit, contrary to the display indication.

If the output is enabled, and the power supply is commanded to operate in Current mode, but
R

L

≥ V

Prog

/ I

Prog

forces the power supply to operate in Voltage mode, the keypad entries adjust

the actual output voltage, contrary to the display indication.

Refer to PAR. 3.2.1.6.3 for procedure.

3.2.1.6.3 PROCEDURE USING VADJ AND NUMERIC KEYPAD

1.

Press Vadj.

TABLE 3-4. USING VADJ AND KEYPAD ENTRIES TO SET

OUTPUT VOLTAGE/VOLTAGE LIMIT — MODELS MR, MGR

POWER SUPPLY STATUS BEFORE Vadj PRESSED

EFFECT AFTER Vadj PRESSED

COMMANDED

MODE

OUTPUT

ENABLED/
DISABLED

ACTUAL MODE ***

(DICTATED BY

LOAD)

DISPLAY

INDICATION

NUMERIC VALUE

SET BY KEYPAD

ADJUSTS:

VOLTAGE

DISABLED

VOLTAGE****

CONST VOLT =

Programmed output voltage

CURRENT

DISABLED

CURRENT****

VOLT LIMIT =

Programmed voltage limit

VOLTAGE

ENABLED

VOLTAGE

CONST VOLT =

Actual output voltage

VOLTAGE

ENABLED

CURRENT *

CONST VOLT =

Actual voltage limit **

CURRENT

ENABLED

CURRENT

VOLT LIMIT =

Actual voltage limit

CURRENT

ENABLED

VOLTAGE *

VOLT LIMIT =

Actual output voltage **

*

Condition where load forces power supply mode.

**

“Overload” error message placed in error buffer (for use when operating in Remote mode).

*** Actual mode is indicated by the VOLTAGE MODE and CURRENT MODE status LED’s.
**** Forced internally by the power supply.

VOLTAGE

MODE

CURRENT

MODE

POLARITY

REVERSED

REMOTE

OUTPUT

ENABLED

STATUS

Const Volt =

###V ###A

VOLTAGE

MODE

CURRENT

MODE

POLARITY

REVERSED

REMOTE

OUTPUT

ENABLED

STATUS

Volt limit =

###V ###A

or

NOTES:

indicates LED may be either on or off.

###V and ###A will either be actual or programmed values of output voltage/voltage
limit and output current/current limit (see Tables 3-3 and 3-4).

indicates that blinking “:” appears only for OUTPUT ENABLED status.