TABLE 3-2. KEY FUNCTIONS

FUNCTION

KEY

DESCRIPTION

REFERENCE

PARAGRAPH

ENTER

ENTER

Used to confirm or enter the input data of the parameter setting.

-

Select alternate

function

SHIFT

Selects alternate function (screened in blue) of keys with dual func-
tion capability. SHIFT key press indicated by blinking “

sh

” on display;

sh

” disappears if valid key (or SHIFT) pressed. When MBT keypad

is used to control another power supply in a remote configuration, the
“sh” changes to .

-

Numeric entries

0 - 9, .

Numerical keys and “.” are used to input all parameter values.

3.2.1.6, 3.2.1.7

CYCLE

PROGRAM

SHIFT then 0

Activated by pressing SHIFT, followed by “0” key when program is
being created or changed. This key function can be pressed at the
end of a local program to indicate that the program is to be recycled
continuously, or to change a program from a “cycle” to “single” run.

3.2.1.11.5

STATUS

SHIFT then”.”

Displays programmed voltage, current, OVP (overvoltage protection),
and OCP (overcurrent protection) on alphanumeric display.

-

Slew voltage or

current

,

Slews the output voltage or current up or down with an increment
which can be set using the menu (see PAR. 3.2.2.6). (Current can be
slewed with these keys only on units commanded to enter Current
mode.) Can also be used to navigate through the screens of each
step of a local program (

goes up,

goes down).

3.2.1.6.4,
3.2.1.6.5,
3.2.1.11

ADD STEP

SHIFT then

Utilized to add steps to program being reviewed, changed, or cre-
ated. Refer to Table 3-16 for default values of new steps.

3.2.1.11.1

DEL (Delete)

STEP

SHIFT then

Utilized to delete displayed step from program being reviewed/
changed. After the step has been deleted, the previous step will be
displayed.

3.2.1.11.4

Display/Adjust

Voltage

Vadj

Utilized to display or adjust either output voltage (Voltage Mode) or
voltage limit (Current Mode).

3.2.1.6.1,
3.2.1.6.2,
3.2.1.6.3,

Command

VOLTAGE MODE

SHIFT then

Vadj

MR, MGR Models: If the unit is commanded to operate in Voltage
mode and the output is disabled, the output relays open (output dis-
abled).

M, MG Models: Unavailable function (“

No Relay presen

t” mes-

sage displayed).

3.2.1.8

Display/Adjust

Current

Iadj

Utilized to display or adjust current limit (Voltage Mode) or output
current (Current Mode).

3.2.1.7.1,
3.2.1.7.2,
3.2.1.7.3

Command

CURRENT MODE

SHIFT then

Iadj

MR, MGR Models: If the unit is commanded to operate in Current
mode and the output is disabled, the output relays close, short-
circuiting the output (output disabled).

M, MG Models: Unavailable function (“

No Relay presen

t” mes-

sage displayed).

3.2.1.8

CLEAR ENTRY

CLEAR ENTRY

Clears the previous keypad entry and is effective if pressed prior to
the ENTER key being pressed. In addition, this key is used to stop a
running program at a step.

3.2.1.11.6
3.2.1.11.7