background image

MBTSVC111609

3-37

14. If Voltage mode is already selected, proceed to step 15. To set Voltage mode, press

SHIFT, then Vadj. (When Current mode is desired, press SHIFT, then Iadj.)

15. Press to display Sc: 3.

16. If Polarity is already set to non-reversed, proceed to step 17. To set Polarity to non-

reversed, press SHIFT, then DC OFF. (Pressing SHIFT then DC OFF will toggle Polarity
between reversed and non-reversed.)

17. Press to display Sc: 4.

18. If Output is already set to Enabled, proceed to step 19. To set Output to Enabled, press DC

ON. (To select Output disabled press DC OFF.)

19. Press to display Sc: 0.

20. Press NEXT to display Sc: 0 for program step 1 (Stp: 1)

.

21. Repeat procedural steps 5 through 12 (steps 5 through 19 for MR and MGR Models) above

to load the values for the screens (0 and 1, or 0 through 4) for program steps 1 and 2 (Stp:1
and Stp: 2) as specified in Table 3-17.

22. Press NEXT to display Stp: 3

3.2.1.11.3 RUNNING A PROGRAM

To run a program you must first enter Program mode (PAR. 3.2.1.11.1). Press SHIFT and
RESET (EXECUTE PROGRAM function) to execute the program once you have selected a pro-
gram, created a new program (PAR. 3.2.1.11.2) or modified a program (PAR. 3.2.1.11.4). While

Pr#2 Stp: 0 Sc:3
Polar nonrevrsed

Pr#2 Stp: 0 Sc:3
Polar reversed

or

Pr#2 Stp: 0 Sc:4
Output enabled

Pr#2 Stp: 0 Sc:4
Output disabled

or

Pr#2 Stp: 0 Sc:0

1.0V 2.10A

Pr#2 Stp: 1 Sc:0

0.0V 0.00A

Stp 3

End of program