KEPCO MBT Series User Manual
Page 83

MBTSVC111609
3-45
12. The functions available from the controlling power supply keypad are:
Voltage Mode
SHIFT then Vadj
Current Mode
SHIFT then Iadj
Change Polarity
SHIFT then DC OFF (for MR, MGR Models only)
Output Enable
DC ON
Output Disable
DC OFF
Voltage Adjust
Vadj, numeric, then ENTER
Current Adjust
Iadj, numeric, then ENTER
Reset
RESET
3.2.2.3.2 REMOTE OPERATION USING KEYPAD TO CONTROL ANOTHER MBT POWER SUPPLY
The following steps are performed at the controlling power supply.
1.
Press MENU ON/OFF to enter the Menu, then press NEXT until “Remote Channel” is
displayed; press ENTER to select this function.
2.
Enter the node number (address) of the power supply to be controlled. This is a number
between 1 and 31 (the node address is set via DIP switch A3S1 accessed through the top
cover; see PAR. 2.6.1). MBT power supplies are shipped with the node address set to a
default value of 1. Enter the node number and press ENTER.
a. If the node address does not exist, or the connection through the IEEE 1118 bus is not
valid, the display will briefly read:
then the unit will return to Menu level with the display reading “Remote Channel.”
Press MENU ON/OFF again to exit the Menu.
b. If the selected unit (node) is present and the control lines operational, the display reads
:
followed by
Enter Node #
Communication
ERROR
wait...
MDL X - Y
NOTE: MDL X -Y refers to the MBT Model, of
the power supply to be controlled (e.g.,
MBT 100-3.6), where X is the nominal
voltage rating (100) and Y is the nomi-
nal current rating (3.6).