beautypg.com

5 preliminary operating procedures, 1 node address (channel number) selection, Table 2-3. node address selection – KEPCO MBT Series User Manual

Page 30: Preliminary operating procedures -6, Node address (channel number) selection -6, Node address selection -6

background image

2-6

MBTSVC 111609

2.5

PRELIMINARY OPERATING PROCEDURES

After the unit is unpacked, and before the unit is installed, the following procedure is required to
set the node address.

2.5.1

NODE ADDRESS (CHANNEL NUMBER) SELECTION

The node address is set by Node Address selector DIP switch A3S1 accessed through the top
cover (see Figure 2-2). The address can be set to any number from 1 to 31 by setting the switch
positions to the binary value as shown in Table 2-3.

TABLE 2-3. NODE ADDRESS SELECTION

DECIMAL

ADDRESS

SELECTOR SWITCH SECTION

(SIGNAL LINE)

A3S1-4

(A4)

A3S1-3

(A3)

A3S1-2

(A2)

A3S1-1

(A1)

A3S1-0

(A0)

1

0

0

0

0

1

2

0

0

0

1

0

3

0

0

0

1

1

4

0

0

1

0

0

5

0

0

1

0

1

6

0

0

1

1

0

7

0

0

1

1

1

8

0

1

0

0

0

9

0

1

0

0

1

10

0

1

0

1

0

11

0

1

0

1

1

12

0

1

1

0

0

13

0

1

1

0

1

14

0

1

1

1

0

15

0

1

1

1

1

16

1

0

0

0

0

17

1

0

0

0

1

18

1

0

0

1

0

19

1

0

0

1

1

20

1

0

1

0

0

21

1

0

1

0

1

22

1

0

1

1

0

23

1

0

1

1

1

24

1

1

0

0

0

25

1

1

0

0

1

26

1

1

0

1

0

27

1

1

0

1

1

28

1

1

1

0

0

29

1

1

1

0

1

30

1

1

1

1

0

31

1

1

1

1

1