Europa-Solar AG
Europa-Solar AG
Solar-Log™ terminal strip connector
RJ45 inverter
Terminal
PIN
► 1
► Pin 3
► 4
► Pin 6
► 5
► Pin 1
► 6
► Pin 2
3. Insert the RJ45 plug into any RJ45 socket on inverter 1.
4. If only one inverter is to be connected terminate this in accordance with the inverter instructions.
5. Close the inverter if no other inverters are to be connected.
6. Insert the terminal block connector into the Solar-Log™ RS485/422 B socket.
Connect the inverters to each other
•
Connect using a network cable (patch cable)
•
Where to connect: RJ45 socket inside the inverter
Procedure
1.
Open the inverter as shown in the inverter's instructions.
2. Insert the RJ45 plug into any RJ45 socket on inverter 1.
3. Insert the other end of the wire into any RJ45 socket on inverter 2.
4. Connect the other inverters to each other in the same way.
5. Terminate in the last inverter according to the inverter instructions.