88 sunville – Solare Datensysteme Solar-Log User Manual
Page 273
![background image](https://www.manualsdir.com/files/860340/content/doc273.png)
273
Sunville
Sunville
88 Sunville
88�1 Sunville
Easy Installation
Termination
Addressing
Interface
Yes
Yes
No
RS422
Overview
•
Interface not integrated; Retrofit RS485 interface card.
•
4-pin cable – only on RS485/422 B connection of the Solar-Log™
•
Communication address does not have to be assigned
•
Multi-string technology
The Sunville inverters are fitted with 1 or 3 MPP trackers depending on the model. Each string input is mo-
nitored separately and ideally adjusted to the connected modules.
The Solar-Log™ automatically detects how many inverters and strings are active during inverter detection.
Note
The order in which the inverters are displayed in the Solar-Log™ after detection is random.
We strongly recommend that you change the order of the inverters immediately after de-
tection at startup, in the
Configuration/Basis/Inverters
dialog box.
The inverters can be identified using the displayed serial number.
•
Installation steps
•
Switch off the inverters and Solar-Log™
•
Install the RS485 interface in the inverter
•
Connect inverters to the Solar-Log™
•
Connect the inverters to each other
Installing the RS485 interface
Procedure
► Insert the RS485 interface in the bottom of the inverter in accordance with the interface card installati-
on instructions and screw in.
Connect inverters to the Solar-Log™
The wiring is done using a
•
ready-made data cable (optional extra; not supplied)
or
•
self-made, shielded 4 wire data cable and terminal block connector.
Note
Only connect inverter using the
RS485/422 B
/C interface.