Note
Only connect inverter using the
RS485/422 B /C
interface�
Procedure
1.
If you are making the cable yourself, connect the wires as shown in the following diagram:
Solar-Log™ terminal strip connector
Inverter terminal strip
Terminal
PIN
► 1
► R+
► 4
► R-
► 5
► T+
► 6
► T-
2. If only one inverter is to be connected terminate this in accordance with the inverter instructions.
3. Insert the terminal block connector into the Solar-Log™ RS485/422 B/C socket
Connect the inverters to each other
•
Connect using a 4 wire, shielded data cable
•
Where to connect: Terminal strip inside the inverter
Procedure
1.
Open the inverter as shown in the inverter's instructions.
2. Connect terminals R+, R-, T+ and T- of inverter 1 to the corresponding terminals on inverter 2.
3. Connect the other inverters to each other in the same way.
4. Terminate in the last inverter according to the inverter instructions.