8 aros solar technology – Solare Datensysteme Solar-Log User Manual
Page 42

42
AROS Solar Technology
AROS Solar Technology (RS422)
8 AROS Solar Technology
8�1
AROS Solar Technology (RS422)
Easy Installation
Termination
Addressing
Interface
No
Yes
No
RS422
Select "Aros 422" during the inverter detection
Overview
•
Integrated interface
•
Where to connect: Terminal strip inside the inverter
•
4-pin cable only on RS485/422 B/C connection of the Solar-Log™
•
Communication address does not have to be assigned
Note:
The order in which the inverters are displayed in the Solar-Log™ after detection is random.
We strongly recommend that you change the order of the inverters immediately after de-
tection at startup in the
Configuration | Device | Configuration | Order
menu box.
The inverters can be identified using the displayed serial number.
•
Installation steps
•
Switch off the inverters and Solar-Log™
•
Connect inverters to the Solar-Log™
•
Connect the inverters to each other
Connect inverters to the Solar-Log™
The wiring is done using a
•
self-made cable connection with terminal block connector.