Solare Datensysteme Solar-Log User Manual
Page 140
![background image](https://www.manualsdir.com/files/860340/content/doc140.png)
140
Kostal and Solar-Fabrik
Kostal Ethernet Version
45�2 Kostal Ethernet Version
Easy Installation
Termination
Addressing
Interface
No
No
Yes
LAN
Overview
•
Integrated interface
•
Connected using network cable (patch cable) and Ethernet router or switch
•
Communication address must be allocated.
•
Installation steps
•
Assign a static IP address
•
Switch off the inverters and Solar-Log™
•
Connect inverters to the Solar-Log™ (RJ45).
•
Connect the inverters to each other (RJ45).
Note:
The RS485 bus address of every inverter has to be configured to 255 so that the Solar-Log
can communicate with the inverter.
=> Starting with firmware version 3.2.1, inverters set up with bus address 1 are supported.
=> The bus address is determined once during the inverter detection process.
For this reason, it is not possible to change it while in operation (the Solar-Log™ would then
no longer be able to access the inverters). If this has accidentally happened, perform the
inverter detection again to be able to access the inverter from the Solar-Log™.
Connect inverters to the Solar-Log™
The wiring is done using a
•
network cable (patch cable/crossover cable) and the
•
Ethernet router or switch.
Connect the inverters to each other
The inverters are connected together using
the RJ45 interface and, if needed, a router or switch.
Connection setup according to the inverter's instructions.
Assigning IP addresses
•
A static IP address has to be assigned to the inverter via the display.
•
Please select an IP address with the same class C subnet as the Solar-Log™.
For example: The Solar-Log™ has the IP address 192.168.178.49.
The inverter in this case has to have a free IP address in the same range (from 192.168.178.1 to
192.168.178.254).
•
Procedure: Start according to the inverter's instructions