11 benning – Solare Datensysteme Solar-Log User Manual
Page 50
![background image](https://www.manualsdir.com/files/860340/content/doc050.png)
50
Benning
Benning
11 Benning
11�1 Benning
Easy Installation
Termination
Addressing
Interface
No
No
Yes
LAN
Overview
•
Integrated interface
•
The inverter's IP address has to be assigned.
•
Connected using network cable (patch cable) and Ethernet router or switch
•
Installation steps
•
The inverter's has to be assigned a static IP address.
•
Switch off the inverters and Solar-Log™
•
Connect inverters to the Solar-Log™ (RJ45).
•
Connect the inverters to each other (RJ45).
Connect inverters to the Solar-Log™
The wiring is done using a
•
network cable (patch cable/crossover cable) and the
•
Ethernet router or switch.
Connect the inverters to each other
The inverters are connected together using
the RJ45 interface and, if needed, a router or switch.
Connection setup according to the inverter's instructions.
Assigning IP addresses
•
A static IP address has to be assigned to the inverter via the display.
•
Please select an IP address with the same class C subnet as the Solar-Log™.
For example: The Solar-Log™ has the IP address 192.168.178.49.
The inverter in this case has to have a free IP address in the same range (from 192.168.178.1 to
192.168.178.254).
•
Procedure: Start according to the inverter's instructions
Note
Each inverter has to be individually reachable via the network. For this, the network inter-
face has to be activated for every inverter (select "Activate LAN" under the LAN menu)
and and the inverter needs to be connected to the local access network (LAN) via a switch.