Easy Installation
Termination
Addressing
Interface
No
No
Yes
LAN
Overview
•
Integrated interface
•
The inverter‘s IP address has to be assigned.
•
Connected using network cable (patch cable) and Ethernet router or switch
•
Installation steps
•
The inverter‘s has to be assigned a static IP address.
•
Switch off the inverters and Solar-Log™
•
Connect inverters to the Solar-Log™ (RJ45).
•
Connect the inverters to each other (RJ45).
Connect inverters to the Solar-Log™
The wiring is done using a
•
network cable (patch cable/crossover cable) and the
•
Ethernet router or switch.
Connect the inverters to each other
The inverters are connected together using
the RJ45 interface and, if needed, a router or switch.
Connection setup according to the inverter‘s instructions.
Assigning IP addresses
•
A static IP address has to be assigned to the inverter via the display.
•
Please select an IP address with the same class C subnet as the Solar-Log™.
For example: The Solar-Log™ has the IP address 192.168.178.49.
The inverter in this case has to have a free IP address in the same range (from 192.168.178.1 to
192.168.178.254).
•
Procedure: Start according to the inverter‘s instructions
Detection from the Solar-Log
™
•
For the detection on the Solar-Log
™
, select „Benning“ as the inverter manufacturer in the
Configu-
ration | Devices | Definition
menu from the
Network
section. Confirm the selection with
Save
.
Detection from the Solar-Log 1200
•
When using the Solar-Log 1200, the detection can also be started from the display. Select „Ben-
ning“ as the manufacturer for the inverter detection from the „network“ interface and start the
detection.