ALPHA-SOL
ALPHA-SOL
7 ALPHA-SOL
7�1
ALPHA-SOL
Easy Installation
Termination
Addressing
Interface
No
Switch
Yes
RS485
Overview
•
Interface not integrated; Retrofit RS485 interface card.
•
4-pin wiring
•
Communication address must be allocated.
•
Installation steps
•
Allocate communication address
•
Switch off the inverters and Solar-Log™
•
Install the RS485 interface in the inverter
•
Connect inverters to the Solar-Log™
•
Connect the inverters to each other
Allocate communication address
•
Recommendation: Continuous numbering starting with 1.
•
Setting: Using the DIP switch on the interface card.
Before
installing the RS485 interface card:
► Allocate the communication address using the 8 interface card DIP switches:
Example - Communication address 1:
On
Off
DIP switch
Example - Communication address 2:
On
Off
DIP switch