Solare Datensysteme Solar-Log User Manual
Page 288

288
Varta Engion Battery System
Varta Engion Battery System
Connect the consumption meter to the Solar-Log™�
The wiring is done using a
•
RS485 or
•
S0 interface.
Assigning IP addresses
•
A static IP address has to be assigned to the battery system.
•
Please select an IP address with the same class C subnet as the Solar-Log™.
For example: The Solar-Log™ has the IP address 192.168.178.49.
The battery system in this case has to have a free IP address in the same range (from 192.168.178.1
to 192.168.178.254).
•
Procedure: Start according to the battery system‘s instructions.
Detection via the Solar-Log
™
WEB interface
•
For the device detection on the Solar-Log
™
select „Varta“ in the
Network
section from the
Confi-
guration | Devices | Definition
menu.
•
Also select the proper interfaces for the meters as well as the inverters. Confirm the selection by
clicking on
Save
.
Detection from the Solar-Log 1200
When using the Solar-Log 1200, the detection can also be started from the display.
•
Select „Varta“ from the „Network“ interface for the detection.
•
Also select the proper interfaces for the meters as well as the inverters and then start the detec-
tion.