103 zeversolar – Solare Datensysteme Solar-Log User Manual
Page 306

306
Zeversolar
Zeversolar
103 Zeversolar
103�1 Zeversolar
Easy Installation
Termination
Addressing
Interface
No
Yes
No
RS422
Overview
•
Interface integrated.
•
Where to connect: RJ45 socket on the outside of the inverter
•
4-pin cable – only on RS485/422 B connection of the Solar-Log™
•
Communication address does not have to be assigned
Note
The order in which the inverters are displayed in the Solar-Log™ after detection is random.
We strongly recommend that you change the order of the inverters immediately after de-
tection at startup, in the
Configuration/Basis/Inverters
dialog box.
The inverters can be identified using the displayed serial number.
•
Installation steps
•
Switch off the inverters and Solar-Log™
•
Install the RS485 interface in the inverter
•
Connect inverters to the Solar-Log™
•
Connect the inverters to each other
Connect inverters to the Solar-Log™
The wiring is done using a
•
ready-made BRJ1 data cable (optional extra; not supplied)
or
•
self-made cable connection with RS485 data cable and terminal block connector.
Caution
Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to the RJ45
socket on the inverter.
► ☻
Only connect inverters via the RS485/422 B- or the RS485/422-C-Solar-Log™ inter-
face.
Note
Only connect inverter using the RS485/422 B or the RS485/422-C-interface.