Wiring the c-series, Wiring the s, mt, p, ts, ts-sv and ht-series – Solare Datensysteme Solar-Log User Manual
Page 237
237
SolarMax
SolarMax – S, C, MT, P, TS, TS-SV and HT- series
Caution
Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to the RJ45
socket on the inverter.
►
Only connect inverters via the RS485/422 Solar-Log™ interface(s).
Wiring the C-series
Procedure
1.
If you are making the cable yourself, connect the wires as shown in the following diagram:
Solar-Log™ terminal strip connector
RJ45 inverter
Terminal
PIN
► 1
► 7
► 2
► 1
► 2
► 2
► 3
► 3
► 3
► 4
5 - unused
6 - unused
► 4
► 8
2. Insert the RJ45 plug into any RJ45 socket on the first inverter.
3. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Wiring the S, MT, P, TS, TS-SV and HT-series
Procedure
1.
If you are making the cable yourself, connect the wires as shown in the following diagram:
Solar-Log™ terminal strip connector
RJ45 inverter
Terminal
PIN
► 1
► 7
► 4
► 8
2. Insert the RJ45 plug into any RJ45 socket on the first inverter.
3. Insert the terminal block connector into the Solar-Log™ RS485 socket.