Easy Installation
Termination
Addressing
Interface
Yes
120
Ω resistor
Yes
RS485
Overview
•
Integrated interface
•
Where to connect: RJ45 socket or COM round sockets on the outside of the inverter
•
2-pin wiring
•
Communication address must be allocated.
•
Installation steps
•
Switch off the inverters and Solar-Log™
•
Connect inverters to the Solar-Log™
•
Connect the inverters to each other
•
Allocate communication address
Note:
The inverter's communication connection is then changed to the from the round socket to
RJ45. Currently, the SG1,5KTL is still supplied with round sockets.
Connect inverters to the Solar-Log™
The wiring is done using a
•
self-made, shielded 2 wire data cable with round plug and terminal block connector.
Procedure
1.
If you are making the cable yourself, connect the wires as shown in the following diagram:
Solar-Log™ terminal strip connector
Round socket inverter for SG1,5KTL
Terminal
PIN
► 1
► 1 (A)
► 4
► 2 (B)