Analog – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual
Page 93

3 Wiring and Connection
3.6.1 Connecting Regenerative Resistors
3-42
(3) SERVOPACKs: Model SGDV-470A, -550A, -590A, -780A, -210D, -260D, -280D, -
370D
No built-in regenerative resistor is provided, so the external regenerative resistor is required. The regenerative
resistor units are as follows:
Note: The regenerative resistor unit is constructed from a number of resistors.
Connect the B1/ and B2 terminals of the SERVOPACK to the R1 and R2 terminals of the regenerative resis-
tor unit.
When using a regenerative resistor unit, leave Pn600 at its factory setting. Set Pn600 when using a non-
YASKAWA external regenerative resistor.
Main Circuit
Power Supply
Applicable
SERVOPACK Model
SGDV-
Applicable
Regenerative
Resistor Unit
Resis-
tance (
Ω)
Specifications
Three-phase
200 V
470A
JUSP-RA04-E
6.25
Four 25
Ω (220 W) resistors are connected
in parallel.
550A, 590A, 780A
JUSP-RA05-E
3.13
Eight 25
Ω (220 W) resistors are connected
in parallel.
Three-phase
400 V
210D, 260D
JUSP-RA18-E
18
Two series of two 18
Ω (220 W) resistors
each are connected in parallel.
280D, 370D
JUSP-RA19-E
14.25
Four series of two 28.5
Ω (220 W) resistors
each are connected in parallel.
Regenerative Resistor Unit
JUSP-RA
-E
SERVOPACK
Analog