Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual
Page 401
11.2 List of Parameters
11-25
11
Ap
pend
ix
Pn460
2
Notch Filter Adjustment
Switch
0000 to 0101
−
0101
Immediately
Tuning
6.2.1
6.3.1
6.5.1
Pn501
2
Zero Clamp Level
0 to 10000
1 min
-1
10
Immediately
Setup
5.3.5
Pn502
2
Rotation Detection Level
1 to 10000
1 min
-1
20
Immediately
Setup
5.10.3
Pn503
2
Speed Coincidence Signal
Output Width
0 to 100
1 min
-1
10
Immediately
Setup
5.3.8
Pn506
2
Brake Reference - Servo OFF
Delay Time
0 to 50
10 ms
0
Immediately
Setup
5.2.4
Pn507
2
Brake Reference Output Speed
Level
0 to 10000
1 min
-1
100
Immediately
Setup
Pn508
2
Waiting Time for Brake Signal
When Motor Running
10 to 100
10 ms
50
Immediately
Setup
Pn509
2
Instantaneous Power Cut Hold
time
20 to 1000
1 ms
20
Immediately
Setup
5.2.6
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Notch Filter Adjustment Selection 1
0
Does not adjust 1st step notch filter automatically using utility function.
1
Adjust 1st step notch filter automatically using utility function.
Reserved (Do not change.)
Notch Filter Adjustment Selection 2
0
Does not adjust 2nd step notch filter automatically using utility function.
1
Adjust 2nd step notch filter automatically using utility function.
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.