Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual
Page 398
11 Appendix
11.2.2 Parameters
11-22
Pn20A
4
Number of External Scale Pitch 4 to 1048576
1
pitch/rev
32768
After restart
Setup
9.3
Pn20E
4
Electronic Gear Ratio
(Numerator)
1 to
1073741824
1
4
After restart
Setup
5.4.4
Pn210
4
Electronic Gear Ratio
(Denominator)
1 to
1073741824
1
1
After restart
Setup
Pn212
4
Encoder Output Pulses
16 to
1073741824
1 P/rev
2048
After restart
Setup
5.3.7
Pn216
2
Position Reference
Acceleration/Deceleration
Time Constant
0 to 65535
0.1 ms
0
Immediately
after the ser-
vomotor stops
Setup
5.4.5
Pn217
2
Average Movement Time of
Position Reference
0 to 10000
0.1 ms
0
Immediately
after the ser-
vomotor stops
Setup
Pn218
2
Reference Pulse Input
Multiplication
1 to 100
1 time
1
Immediately
Setup
5.4.3
Pn22A
2
Fully-closed Control Selection
Switch
0000 to 1003
−
0000
After restart
Setup
−
Pn281
2
Encoder Output Resolution
1 to 4096
1 edge/
pitch
20
After restart
Setup
9.3.3
Pn300
2
Speed Reference Input Gain
150 to 3000
0.01V
/rated
speed
600
Immediately
Setup
5.3.1
5.5.4
6.9.3
Pn301
2
Internal Set Speed 1
0 to 10000
1 min
-1
100
Immediately
Setup
5.6.1
Pn302
2
Internal Set Speed 2
0 to 10000
1 min
-1
200
Immediately
Setup
Pn303
2
Internal Set Speed 3
0 to 10000
1 min
-1
300
Immediately
Setup
Pn304
2
JOG Speed
0 to 10000
1 min
-1
500
Immediately
Setup
7.3
Pn305
2
Soft Start Acceleration Time
0 to 10000
1 ms
0
Immediately
Setup
5.3.3
Pn306
2
Soft Start Deceleration Time
0 to 10000
1 ms
0
Immediately
Setup
Pn307
2
Speed Reference Filter Time
Constant
0 to 65535
0.01 ms
40
Immediately
Setup
5.3.4
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Speed Feedback Selection at Fully-closed Control
Reference
Section
0
Uses motor encoder speed.
9.3.8
1
Uses external encoder speed.
4th 3rd 2nd 1st
digit digit digit digit
n.