Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual
Page 396

11 Appendix
11.2.2 Parameters
11-20
Pn162
2
Anti-Resonance Gain
Compensation
1 to 1000
1%
100
Immediately
Tuning
−
Pn163
2
Anti-Resonance Damping Gain
0 to 300
1%
0
Immediately
Tuning
−
Pn164
2
Anti-Resonance Filter Time
Constant 1 Compensation
-1000 to 1000
0.01 ms
0
Immediately
Tuning
−
Pn165
2
Anti-Resonance Filter Time
Constant 2 Compensation
-1000 to 1000
0.01 ms
0
Immediately
Tuning
−
Pn170
2
Tuning-less Function Related
Switch
0000 to 2411
−
1401
−
–
–
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Tuning-less Function Selection
When
Enabled
Classification
Reference
Section
0
Disables tuning-less function.
After restart
Setup
6.2
1
Enables tuning-less function.
Control Method during Speed Control
When
Enabled
Classification
Reference
Section
0
Uses as speed control.
After restart
Setup
6.2
1
Uses as speed control and uses the host controller for
position control.
Rigidity Level
When
Enabled
Classification
Reference
Section
0 to 4
Sets rigidity level.
Immediately
Setup
6.2
Load Level
When
Enabled
Classification
Reference
Section
0 to 2
Sets load level.
Immediately
Setup
6.2
4th 3rd 2nd 1st
digit digit digit digit
n.