Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual
Page 389
11.2 List of Parameters
11-13
11
Ap
pend
ix
Pn006
2
Application Function Select
Switch 6
0000 to 005F
−
0002
Immediately
Setup
6.1.3
Pn007
2
Application Function Select
Switch 7
0000 to 005F
−
0000
Immediately
Setup
6.1.3
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Analog Monitor 1 Signal Selection
00
Motor rotating speed (1 V / 1000 min
-1
)
01
Speed reference (1 V / 1000 min
-1
)
02
Torque reference (1 V/100% rated torque)
03
Position error (0.05 V/1 reference unit)
04
Position amplifier error (after electronic gears) (0.05 V/ 1 encoder pulse unit)
05
Position reference speed (1 V / 1000 min
-1
)
06
Reserved (Do not use.)
07
Motor-load position error (0.01 V/1 reference unit)
08
Positioning completion (positioning completed: 5 V, positioning not completed: 0 V)
09
Speed feedforward (1 V / 1000 min
-1
)
0A
Torque feedforward (1 V/100% rated torque)
0B
Active gain (1st gain: 1 V, 2nd gain: 2 V)
0C
Completion of position reference (completed: 5 V, not completed: 0 V)
0D
External encoder speed (1 V / 1000 min
-1
: Values at motor shaft)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Analog Monitor 2 Signal Selection
00
Motor rotating speed (1 V / 1000 min
-1
)
01
Speed reference (1 V / 1000 min
-1
)
02
Torque reference (1 V/100% rated torque)
03
Position error (0.05 V/1 reference unit)
04
Position amplifier error (after electronic gears) (0.05 V/ 1 encoder pulse unit)
05
Position reference speed (1 V / 1000 min
-1
)
06
Reserved (Do not use.)
07
Motor-load position error (0.01 V/1 reference unit)
08
Positioning completion (positioning completed: 5 V, positioning not completed: 0 V)
09
Speed feedforward (1 V / 1000 min
-1
)
0A
Torque feedforward (1 V/100% rated torque)
0B
Active gain (1st gain: 1 V, 2nd gain: 2 V)
0C
Completion of position reference (completed: 5 V not completed: 0 V)
0D
External encoder speed (1 V / 1000 min
-1
: Values at motor shaft)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.