5.10 Other Output Signals
5-79
5
Ope
rat
ion
5.10 Other Output Signals
This section explains other output signals.
Use these signals according to the application needs, e.g., for machine protection.
5.10.1 Servo Alarm Output Signal (ALM) and Alarm Code Output Signals (ALO1,
ALO2, and ALO3)
This section describes signals that are output when the SERVOPACK detects errors and resetting methods.
(1) Servo Alarm Output Signal (ALM)
This signal is output when the SERVOPACK detects an error.
(2) Alarm Code Output Signals (ALO1, ALO2, and ALO3)
The ON/OFF combination of these signals specifies the type of alarm detected by the SERVOPACK.
Use these signals as required to display the contents of the alarm at the host controller.
For details, refer to 10.1.1 List of Alarms.
Configure an external circuit so that this alarm output turns OFF the main circuit power
supply for the SERVOPACK whenever an error occurs.
Type
Signal
Name
Connector
Pin Number
Setting
Meaning
Output
ALM
CN1-31, 32
ON (closed)
Normal SERVOPACK status
OFF (open)
SERVOPACK alarm status
Type
Signal Name
Connector
Pin Number
Meaning
Output
ALO1
CN1-37
Alarm code output
ALO2
CN1-38
Alarm code output
ALO3
CN1-39
Alarm code output
SG
CN1-1
Signal ground for alarm code output