3.1 Main Circuit Wiring
3-9
3
Wi
ring an
d Conn
ecti
on
(5) How to Select Molded-case Circuit Breaker and Fuse Capacities
The following table shows the SERVOPACK’s current capacities and inrush current.
Select a molded-case circuit breaker and fuses in accordance with these specifications.
Note 1. To comply with the EU low voltage directive, connect a fuse to the input side as protection against accidents
caused by short-circuits.
Select fuses or molded-case circuit breakers that are compliant with UL standards.
The table above also provides the net values of current capacity and inrush current. Select a fuse and a molded-
case circuit breaker which meet the breaking characteristics shown below.
• Main circuit, control circuit: No breaking at three times the current values shown in the table for 5 s.
• Inrush current: No breaking at the current values shown in the table for 20 ms.
Main
Circuit
Power
Supply
Maximum
Applicable
Servomotor
Capacity
[kW]
SERVO-
PACK
Model
SGDV-
Power Sup-
ply Capacity
per SER-
VOPACK
[kVA]
Current Capacity
Inrush Current
Main Circuit
[Arms]
Control
Circuit
[Arms]
Main Circuit
[A0-p]
Control
Circuit
[A0-p]
Single-
phase,
100 V
0.05 R70F
0.2
1.5
0.38
16.5
35
0.1 R90F
0.3
2.5
0.2 2R1F
0.7
5
0.4 2R8F
1.4
10
Three-
phase,
200 V
0.05 R70A
0.2
1.0
0.2
33
70
0.1 R90A
0.3
1.0
0.2 1R6A
0.6
2.0
0.4 2R8A
1
3.0
0.5
3R8A
1.4
3.0
33
0.75 5R5A
1.6
6.0
1.0
7R6A
2.3
6.0
1.5
120A
3.2
7.3
0.25
2.0
180A
4
9.7
3.0
200A
5.9
15
5.0
330A
7.5
25
0.3
65.5
6.0
470A
10.7
29
7.5
550A
14.6
37
11
590A
21.7
54
0.45
109
48
15
780A
29.6
73
Three-
phase,
400 V
0.5
1R9D
1.1
1.4
1.2
17
–
1.0
3R5D
2.3
2.9
1.5
5R4D
3.5
4.3
2.0
8R4D
4.5
5.8
1.4
34
3.0
120D
7.1
8.6
5.0
170D
11.7
14.5
57
6.0
210D
12.4
17.4
1.5
34
7.5
260D
14.4
21.7
11
280D
21.9
31.8
1.7
68
15
370D
30.6
43.4