1 list of monitor displays – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual
Page 318
8 Monitor Displays (Un
)
8-2
8.1 List of Monitor Displays
The monitor displays can be used for monitoring the I/O signal status, and SERVOPACK internal status.
Refer to the following table.
∗1. For details, refer to 8.4 Monitoring Input Signals.
∗2. For details, refer to 8.5 Monitoring Output Signals.
∗3. For details, refer to 8.3 Reading 32-bit Data in Decimal Displays.
∗4. For details, refer to 5.4.4 Electronic Gear.
∗5. For details, refer to 9.3.3 Setting Encoder Output Pulses (PAO, PBO, and PCO).
∗6. If the reference pulse input multiplication switching function is enabled, the reference pulse will be multiplied by n to
obtain the reference. This function is supported by software version 001A or later.
∗7. The monitor Un022 can be used only with SGDV-
B SERVOPACKs. For details, refer to 2 Installation
of
Σ
-V Series USER’S MANUAL, Setup, Rotational Motor (No.: SIEP S800000 43).
Parameter
No.
Description
Unit
Un000
Motor rotating speed
min
-1
Un001
Speed reference
min
-1
Un002
Internal torque reference (in percentage to the rated torque)
%
Un003
*3
Rotational angle 1 (encoder pulses from the phase-C origin:
decimal display)
encoder pulse
∗4
Un004
Rotational angle 2 (from polarity origin (electric angle))
deg
Un005
*1
Input signal monitor
−
Un006
*2
Output signal monitor
−
Un007
*6
Input reference pulse speed (valid only in position control)
min
-1
Un008
*6
Position error amount (valid only in position control)
reference unit
Un009
Accumulated load ratio (in percentage to the rated torque:
effective torque in cycle of 10 seconds)
%
Un00A
Regenerative load ratio (as a percentage of the processable
regenerative power: regenerative power consumption in cycle
of 10 seconds)
%
Un00B
Power consumed by DB resistance
(in percentage to the processable power at DB activation: dis-
played in cycle of 10 seconds)
%
Un00C
*3, *6
Input reference pulse counter
reference unit
Un00D
*3
Feedback pulse counter
encoder pulse
∗4
Un00E
*3
Fully-closed feedback pulse counter
external encoder resolution
∗5
Un012
Total operation time
100 ms
Un013
*3
Feedback pulse counter
reference unit
Un014
Effective gain monitor (gain settings 1 = 1, gain settings 2 = 2)
−
Un015
Safety I/O signal monitor
−
Un020
Motor rated speed
min
-1
Un021
Motor maximum speed
min
-1
Un022
*7
Installation environment monitor
(Operation conditions in various environments can be moni-
tored.)
%