3 servopack ratings and specifications, 1 ratings, 1) sgdv with single-phase, 100-v rating – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual
Page 23: 2) sgdv with single-phase, 200-v rating, 3) sgdv with three-phase, 200-v rating
1.3 SERVOPACK Ratings and Specifications
1-3
1
Outline
1.3 SERVOPACK Ratings and Specifications
This section describes the ratings and specifications of SERVOPACKs.
1.3.1 Ratings
Ratings of SERVOPACKs are as shown below.
(1) SGDV with Single-phase, 100-V Rating
∗ Refer to 3.6 Connecting Regenerative Resistors for details.
(2) SGDV with Single-phase, 200-V Rating
∗1. The official model number is SGDV-120A01A008000.
∗2. Refer to 3.6 Connecting Regenerative Resistors for details.
(3) SGDV with Three-phase, 200-V Rating
∗ Refer to 3.6 Connecting Regenerative Resistors for details.
SGDV (Single Phase, 100 V)
R70
R90
2R1
2R8
Continuous Output Current [Arms]
0.66
0.91
2.1
2.8
Instantaneous Max. Output Current [Arms]
2.1
2.9
6.5
9.3
Regenerative Resistor *
None or external
Main Circuit Power Supply
Single-phase, 100 to 115 VAC
, 50/60 Hz
Control Power Supply
Single-phase, 100 to 115 VAC
, 50/60 Hz
Overvoltage Category
III
+10%
–15%
+10%
–15%
SGDV (Single Phase, 200 V)
120
*1
Continuous Output Current [Arms]
11.6
Instantaneous Max. Output Current [Arms]
28
Regenerative Resistor
*2
Built-in or external
Main Circuit Power Supply
Single-phase, 220 to 230 VAC
, 50/60 Hz
Control Power Supply
Single-phase, 220 to 230 VAC
, 50/60 Hz
Overvoltage Category
III
+10%
–15%
+10%
–15%
SGDV (Three Phase, 200 V) R70 R90 1R6 2R8 3R8 5R5 7R6 120 180 200 330 470 550 590 780
Continuous Output Current
[Arms]
0.66 0.91 1.6
2.8
3.8
5.5
7.6 11.6 18.5 19.6 32.9 46.9 54.7 58.6 78.0
Instantaneous Max. Output
Current [Arms]
2.1
2.9
5.8
9.3 11.0 16.9 17
28
42
56
84
110 130 140 170
Regenerative Resistor
*
None or external
Built-in or external
External
Main Circuit Power Supply
Three-phase, 200 to 230 VAC
, 50/60 Hz
Control Power Supply
Single-phase, 200 to 230 VAC
, 50/60 Hz
Overvoltage Category
III
+10%
–15%
+10%
–15%