2 zero-clamp, Input /p-con cn1-*1 – Yaskawa Sigma Mini User Manual
Page 85

2.4Setting Stop Mode
— 2-41 —
2.4.2 Zero-clamp
What is the Zero-clamp Function?
The zero-clamp function is used for a system in which the host controller does not form a posi-
tion loop by speed reference input.
In other words, this function is used to stop the motor and enter a servo locked status when
the input voltage of speed reference V-REF is not 0 V. When the zero-clamp function is turned
ON, an internal position loop is temporarily formed, causing the motor to be clamped within
one pulse. Even if the motor is forcibly rotated by external force, it returns to the zero-clamp
position.
Host controller
Speed reference
Speed reference less than
Cn-0A setting is ignored
Stops
instantaneously
/P-CON
C
N
5
CN3
CN4
CN2
CN1
Set the following memory switch so that input signal /P-CON can be used to enable or disable
the zero-clamp function.
Cn-01Bit A
Control Mode Selection
Factory
Setting:0
For Speed/Torque Control
Cn-01Bit B
Control Mode Selection
Factory
Setting:0
For Speed/Torque Control
→ Input /P-CON CN1-*1
Proportional Control, etc.
For Speed/Torque
Control and
Position Control
2
Speed/Torque
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)