Yaskawa Sigma Mini User Manual
Page 231

5.2 Error Diagnosis and Troubleshooting
— 5-11 —
Cause
Remedy
A
Encoder wiring incorrect or poor
connection.
Check wiring and connectors at encoder.
B
Noise in encoder wiring.
Separate encoder wiring from main wiring
circuits.
C
Encoder defective.
Replace Servomotor.
D
Circuit board (1PWB) defective.
Replace Servopack.
13.CPF00
Display and Outputs
Digital Operator Display
Alarm Name
Alarm Output
CPF00
Digital Operator transmission
error 1
Not specified.
Note
This alarm is not stored in alarm traceback function memory.
Status when Alarm Occurred
A
,
B
,
C
,
D
At power ON. Digital
Operator connected be-
fore Servopack power
turned ON.
Digital Operator con-
nected to Servopack after
power turned ON.
A
,
B
,
C
,
D
Cause
Remedy
A
Cable defective or poor contact between
Digital Operator and Servopack.
• Check connector connections.
• Replace cable.
B
Malfunction due to external noise.
Separate Digital Operator and cable from
noise source.
C
Digital Operator defective.
Replace Digital Operator.
D
Servopack defective.
Replace Servopack.
14.CPF01
Display and Outputs
Digital Operator Display
Alarm Name
Alarm Output
CPF01
Digital Operator transmission
error 2
Not specified.
Note
This alarm is not stored in alarm traceback function memory.
Status when Alarm Occurred
A
,
B
,
C
,
D
During operation
5